The new preloaded patch panel is specifically designed for installation in data centres where the high density, angeld design for improved patch cord management and enhanced installation benefits of the patch panel meet the key requirements for implementation.
The patch panels are preloaded with LC adaptors and are available in medium and high density versions. The medium density patch panel provides 48 LC connections, while the high density version has 96 LC connections. Singlemode and multimode versions are available.
The angular shape is matching the shape of the Nexans copper V-shape panel. This shape is perfectly suited to guide the patch cords horizontally to the side of the panel.
The newly developed tray of the patch panel can be removed from the rack completely to ease installation of direct terminated or spliced fibre and faster installation of Pre-Term fibre.
The preloaded patch panel has extended rear cable management with multiple entries to provide maximum flexibility. It accommodates both cable glands and tie wraps for strain relief of the cables. The cable gland sizes are 20 mm (8x) and 25 mm (2x).
For improved fibre management the fibres can be arranged in 4 separate loops for added flexibility and organisation. The support bases and the rings for these 4 loops are included as standard.
The patch panel tray has multiple, specially designed, slots at the rear to fix the cable glands of Nexans’ pre-terminated cables. There is ample space inside the patch panel to organise the flexible fan-out of the pre-terminated cables.
Up to 4 splice cassettes (N890.090 and N890.091) can be installed inside the tray of the patch panel. Only one cover (N890.092) is required to close the splice cassettes at the top. The bottom splice cassette is fixed with screws to the tray of the patch panel. Splice cassettes are fixed with hinges to the cassette below and with such an installation the splice cassettes can be lifted and tilted for improved access to the splices inside the patch panel. This facilitates the inspection of the splices after installation.
Each splice cassette for heat shrink protection (N890.090) can accommodate 12 splices allowing a maximum of 48 splices for the complete patch panel.
The splice cassette for aluminium protection (N890.091) has a maximum of 24 splices resulting in a maximum of 96 splices per patch panel. N890.091 can only be used with maxistrip pigtails and cables with 250 um fibres.
Splice cassettes are not included in the patch panel and must be ordered separately.
Panels are fully painted in black for a professional look and feel.
|