2 x 2 x 0.22mm²
The cables are used in windturbines. Among other things the CanBus cable connects the hub-box with a box in nacelle. Notice that the cable is exposed too high temperature in the gearbox and main shaft and in contact with gear and hydraulic oil
Insulation: TPE compound Colour Code: 4 Cores White-Green-Brown-Yellow Diameter: 1.40 ± 0.1 mm
Center: Fibrillated polypropilene filler Layer: 4 Cores twisted together in quad (Sequence White-Green-Brown-Yellow) + polyester tape. Can Bus pairs White+Brown , Green+Yellow
Aluminium/Polyester Tape (alu outside) braided screen of tinned copper wires (Coverage ≥ 85%) + non woven tape
Cable marking:
CABLOSWISS – Week/Year of production - WINDLINK CAN BUS PUR 2x2x0.22mm² Meter marking Marking according to DIN47100
Mechanical properties of insulation and sheathing compound: The cable has to fulfil relevant tensile and elongation tests according to IEC60811-1-1, clause 9
The cable has to be oil resistant. Test according to EN60811-2-1 (based on to IEC60811-2-1) Standard test oil ASTM No. 2 24h at 100°C Max tensile strength variation: +/- 40% (HD22.10, attachment A) Max change of elongation at break: +/- 40% (HD22.10, attachment A)
Additional the cable has to be resistant to the used gear-and hydraulic oil. Gear oil: Tribol 1710/320 150 days at 100°C Hydraulic oil: Mobil DTE 13 M, Shell Tellus Arctic 32, Castrol AWH-M 32 140 days at 100°C
Max tensile strength variation: - 50% Max change of elongation at break: - 50%
Thermal endurance graph (Arrhenius) and life expectancy of sheath material acc. to ISO2578 Gear oil: 18 years at 65°C (more than 25 years at 20°C) Hydraulic oil: 24 years at 65°C (more than 25 years at 20°C)
The cable has to have low emission of smoke. Smoke visibility according to EN50268 (based on IEC61034)
Level for smoke visibility is >35%
Halogen free - Low emission of corrosive gases (acidic gases): The cable has to be halogen free, have low emission of corrosive gases and acid. Halogen free – without Chlorine, Fluorine and Bromine Corrosive gases and acid content according to HD22.13 and EN50267-1 and EN50267-2 (based on IEC60754) Gases from burned cables have a conductivity < 10µS/mm and pH > 4.3
Vibrations continuously affect the cables. Bending radius:
Permissible pulling force > 15 N/mm2
Impedance at 1MHz: 120 Ohm +/-15%
Conductor resistance, max.: 98.0 Ohm/km @20°C
Capacitance at 800Hz, nominal: 41nF/km
Insulation resistance, min.: 1 GOhmxkm (20°C and 500V)
Test voltage (AC, 1 min) 1.2kV (core/core and core/screen)
Cable sheath shall be provided with:
About Sheath surface: