English Log ind Bliv registreret Catalog Browser Contact Us
Global ekspert i kabler og kabelsystemer

Nexans

Produkter og løsninger

Kunde service

Job hos Nexans

Nyheder og presse

Enter

WINDLINK® UL/CSA EPR/CPE 1000V 90°C

Bookmark print Contact Us
WINDLINK® UL/CSA EPR/CPE 1000V 90°C

Appliance Wiring Material UL 758 standard certified
1000 V – 90°C
Style 3850 for single cores & Style 4558 for multi-cores
UL/CSA 22.2
AWM class I, II, or I / II , Group A,B, or A/B

UL CSA
Beskrivelse

Application

This cable is specially designed for Wind Turbines

The quality of material used for insulation and sheathing and high quality copper conductors make the cables both flexible, durable, resistant to torsion and to high temperatures. Nexans offers more than a decade of experience in the wind energy market. Our expertise makes WINDLINK® cables highly recommended for wind turbines.

 

Main characteristics

  • Frequent torsion: Excellent torsion behavior
  • Industrial cables resistant to high temperatures
  • Heavy duty
  • Temperature on core: 90°C in normal use; 250°C in short circuit
  • Water resistance: AD2, AD6
  • Corrosive and polluting substances resistance: AF3
  • Outdoor use : temporary and permanent
  • Impact resistance: AG2
  • Oil resistant ASTM/IRM 902
  •  UV resistant for external application
  • Ozone resistant
  • Flame retardant (IEC/EN 60332-1)

 

Design 

1. Conductor :
Annealed plain copper-  Optional tape
Flexible (fine wire class 5 of IEC/EN 60228)

2. Insulation :
Special thermoset EPR for high temperature
Optional tape on insulation or assembling

3. Sheath:
High mechanical performance , oil resistant
Ozone resistant, ref HD 22.1, black colour
Special thermoset CPE improved for low temperature behaviour (-40°C)
 


 TOP
Tekniske data
Konstruktion
Lederens materiale Plain annealed copper  
Elektriske egenskaber
Mærkespænding Uo/U 1000 V  
Mekaniske egenskaber
Torsion test max. +/- 4 turns for 10 meters max:150° per meter  
Mekanisk modstand til impacts Godt  
Tensile strength 15N/mm2  
Håndteringsinformation
Maksimal kærne temperatur 90°C  
Maksimum kortslutningstemperatur – leder 250°C  
Minimum drifttemperatur -40°C  
Omgivelsestemperatur installation, område -40 .. 80°C  
Ambient dynamic operating temperature, range -40 .. 50°C  
Drifttemperatur, område -40 .. 90°C  
Ambient static operating temperature, range -40 .. 50°C  
Olie modstand Good  
U.V bestandig Very good  
Watertightness AD2 to AD6  

 TOP
Søg parameter
Leder tværsnit  mm²
Antal af ledere  
Outer diameter acc Windturbines needs Min Max  mm
Vælg
Reset
Deres valg   4/4
Vælg alle produkter Nexans ref. Leder tværsnit (mm²) Antal af ledere Outer diameter acc Windturbines needs Min Max (mm)
1 x 35 7,6 1 15.5 .. 18.5
1 x 185 18 1 28.0 .. 32.0
4 G 1.5 1,5 4 11.7 .. 14.0
4 G 35 7,6 4 32.5 .. 40.0
Tilføj til favorit

 TOP
Complementary technical for Windlink®

Usage characteristics:

Mechanical stress :

(on the whole cable, per mm² of a cross section of plain copper core)

  • In normal use : 15 N/mm²

 

Mechanical characteristics:

Bending Radius

Mobile use = 6 x External diameter.
Static use = 3 x External diameter , if the external diameter < 12mm, 4 x if the external diameter >12 mm.

 

Electrical characteristics:

Permissible current rating: 

  • Permanent temperature of operation on the core 90°C
  • Ambient temperature for an outdoor installation  30°C

 

Correction factors according for other ambient temperature : according to IEC 60364.5.523 table 52.D1 or DIN VDE 0298-4 Table 15

Ambient
temperature (°C)
10 15 20 25 30 35 40 45 50 55 60 65 70 75
factors  1.17 1.13 1.09 1.04 1 0.96 0.91 0.87 0.82 0.76 0.69 0.62 0.54 0.45

The Voltage drop has been determined with Cos φ= 0.8

 

 Short circuit : constant K=139 Amps for 1 second, acc.to IEC 60949 ( short circuit temperature +250°C and conductor temperature +90°C)

 

 


 TOP
UL/CSA EPR/CPE 1000V

Other properties

Standard tests according to UL 758 standard style 3850 (single core), style 4558 (multi-core cables)
UV resistant sheath black sheath is UV resistant for external application
Oil resistant sheath good in oils, greases, gear box oil, etc
  • ASTM/IRM 902
24h at 100°C
  • Gear box oil as Tribol 1710/320 or equiv oil.
72h at 40°C or 24 h at 100°C
  • Hydraulic oil Mobil DTE 13m or equiv oil.
72h at 40°C or 24 h at 100°C

 TOP
Salgs og leveringsinformationer

Marking

WINDLINK® NEXANS 213
Nb cores X (or G) S
X = without G/Y
G = with G/Y
S = cross section (mm2)
+ "UL/CSA" marking
Week + year manufacturing
meter marking

 

Insulated Cores identification

• 1 core = Black (preferential)
• 2 cores = Brown + Blue
• 3 cores = Green/Yellow +Blue + Brown (G)
Brown + Black + Grey (X S>4mm²)
Blue + Brown + Black (X S 1.5 & 2.5 mm²)
• 4 cores = Green/Yellow + Brown + Black + Grey (G)
Blue + Brown + Black + Grey (X S 1.5 & 2.5 mm²)


Nexans © copyright 2001 - 2012   Legal Notice | Kontakt os | Site Map